Features:

Switch Mode Power Supplies - Enclosed - 100 Watt
  • Compact-Economical
  • High efficiency
  • Convection cooled
  • Great reliability
  • Wide input range
  • 100% burn-in test
  • UL1950 and CUL1950 approval
  • CE marking & compliance with EN61000-3-2
  • Built-in line filter
  • 2 years warranty
  • MOSFET designed

General Specification:

  • Input Voltage............................. 100-240VAC
  • Input Frequency.......................... 47-63Hz
  • Inrush Current (cold) .................. 25A/110VAC 50A/220VAC
  • Operation Temperature ............... 0°C-50°C
  • Storage Temperature................... -20°C-85°C
  • Short Protection .......................... Autorecovery
  • Overload Protection ..................... Automatic Power Limited
  • Hold-upTime .............................. 16mS
MODEL O/P Volts
Adj.± %
Load(current) Ripple
& Noise
Line
REG.
Load
REG.
Efficiency O.V.P.
Trip point
Min. Rated Max.
PPRP1100-5F V1:+5V±10% 0A 20A 20A 50mVp-p ±1% ±1% 69% Min. -
PPRP1100-8F V1:+8V±10% 0A 12.5A 12.5A 80mVp-p ±1% ±1% 73% Min. -
PPRP1100-12F V1:+12V±10% 0A 8.3A 8.3A 100mVp-p ±1% ±1% 75% Min. -
PPRP1100-15F V1:+15V±10% 0A 6.7A 6.7A 150mVp-p ±1% ±1% 75% Min. -
PPRP1100-18F V1:+18V±10% 0A 5.6A 5.6A 150mVp-p ±1% ±1% 75% Min. -
PPRP1100-24F V1:+24V±10% 0A 4.2A 4.2A 150mVp-p ±1% ±1% 77% Min. -
PPRP1100-48F V1:+48V±10% 0A 2.1A 2.1A 250mVp-p ±1% ±1% 82% Min. -
PPRP21001F V1:+8V±10% 0A 12A 12.5A 80mVp-p ±1% ±1% 70% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21002F V1:+12V±10% 0A 8A 8.3A 100mVp-p ±1% ±1% 70% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21003F V1:+24V±10% 0A 4A 4A 150mVp-p ±1% ±1% 74% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21004F V1:+13V±10% 0A 7.4A 7.4A 100mVp-p ±1% ±1% 75% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21005F V1:+16V±10% 0A 6A 6A 150mVp-p ±1% ±1% 75% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21006F V1:+18V±10% 0A 5.3A 5.3A 150mVp-p ±1% ±1% 74% Min. -
V2:+5V±10% 0A 0.8A 0.8A 50mVp-p ±1% ±1%
PPRP21008F V1:+12V----- 0A 7A 7A 150mVp-p ±3% ±7% 75% Min. -
V2:+5V±10% 0A 2A 2A 50mVp-p ±1% ±2%
PPRP21009F V1:+24V±10% 0A 3A 3A 100mVp-p ±1% ±2% 79% Min. -
V2:+12V---- 0A 2A 2A 100mVp-p ±3% ±6%
PPRP40851F V1:+5V±10% 0A 2A 2A 50mVp-p ±1% ±2% 74% Min. -
V2:+24V----- 0A 3A 3A 150mVp-p ±1% ±8%
V3:+15V----- 0A 0.3A 0.3A 150mVp-p ±2% ±5%
V4:-15V----- 0A 0.3A 0.3A 150mVp-p ±2% ±5%
PPRP41001F V1:+5V±10% 0A 3A 3A 50mVp-p ±1% ±2% 72% Min. -
V2:+15V----- 0A 5.5A 5.5A 150mVp-p ±2% ±8%
V3:+18V----- 0A 0.5A 0.5A 150mVp-p ±2% ±8%
V4:+30V----- 0A 0.07A 0.07A 200mVp-p ±2% ±10%
Switch Mode Power Supplies - Enclosed - 100 Watt

Notes:
Each output can provide up to maximum load, but total load cannot exceed rated output power. Ripple & Noise is measured by using a 0.1 µF/630V metalized capacitor & a 47 µF electrolytic capacitor parallel on the test point, at rated load and 110VAC input. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 20% to 100% of rated load at 110VAC input. Efficiency is measured at rated load and 110VAC input.